Kellow · 1981Published duct-wall temperature measurements.
Poradowski et al. · 202618 published full-FEM cases.
Aegerter & Meier · 2019Longitudinal tunnel airflow reference.
SINTEF · 2026Laboratory data for tunnel ventilation.
Explore further sources & verification checks
Further published sources
Pilgrim et al. · 2012Natural-ventilation reference.
Neginhal et al. · 2026Ventilation and enclosure opening correlations.
Fu · 2021Additional source recorded in the validation basis.
Papadakis · Rutherford · Thyvrin · Ferreira · 2026Further papers in the current reference set.
Numerical verification
Mesh refinement & domain sensitivityCheck the effect of numerical resolution and boundaries.
Energy balance, reciprocity & symmetryCheck numerical consistency.
Independent SciPy FEM cross-solveCompare independent numerical implementations.
Multiple-system invarianceCheck behaviour across circuit counts.
How evidence is reported
PassAgreement within the tolerance stated by the source.
Pass with limit or caveatSource-specific bounds and deviations remain visible.
Source evidenceMeasured data retained for comparison; not a pass/fail result.
The validation register distinguishes benchmark agreement, qualified results and supporting source evidence. Each calculation records its engine release and hash for traceability.
PRICING / START WITH A REAL PROJECT
Try the calculation. Then choose your scope.
Start free. Explore the complete workspace for 14 days. Upgrade when your work calls for it.
AmpaCore Free
A focused workspace for direct-buried cable engineering.
Seat 2: 20% off · Seat 3: 30% off · Seat 4: 40% off · Seats 5+: 50% off. First seat: €299 monthly or €2,990 annually. All prices exclude applicable taxes.
Compare engineering capabilities16 capabilities. Four platforms. A closer look at the scope.
Capability
AmpaCore
CYMCAP Eaton
Grøft Design
ELEK Cable HV
Thermal rating
IEC 60287 steady-state
✓Supported
✓Supported
✓Supported
✓Supported
IEC 60853 cyclic and emergency
✓Supported
✓Supported
◐Limited
◐Limited
Finite element method
✓Supported
◐Limited
✓Supported
◐Limited
Soil dry-out
✓Supported
◐Limited
✓Supported
✓Supported
Circuit crossings (IEC 60287-3-3)
✓Supported
◐Limited
—
✓Supported
3D / non-parallel geometry
—
◐Limited
—
—
Bonding and electrical
Cross-bonded, single-point, both-ends
✓Supported
✓Supported
✓Supported
✓Supported
Standing sheath voltage profile
✓Supported
✓Supported
—
✓Supported
IEC 60949 short-circuit rating
✓Supported
◐Limited
—
✓Supported
Sequence impedances
—
◐Limited
—
✓Supported
HVDC cables
—
✓Supported
—
◐Limited
Installation types
Direct buried, backfill, ducts
✓Supported
✓Supported
✓Supported
✓Supported
HDD ampacity profile
✓Supported
—
—
—
Troughs, tunnels
✓Supported
◐Limited
—
✓Supported
Submarine, seabed, J-tubes
✓Supported
◐Limited
—
◐Limited
Multi-section routes, mixed methods
✓Supported
◐Limited
—
◐Limited
✓ Supported◐ Limited, partial or add-on— Not available or not identified
“Limited” may include a separately licensed module. A dash means the capability was unavailable or was not identified in the product material reviewed. Confirm current scope with each vendor. All trademarks belong to their respective owners.
CONTACT / TALK TO ELERU
Let’s talk about your cable system.
Questions about engineering scope, pricing or AmpaCore? Get in touch with Eleru directly.